Be careful when using anything with a high electrical draw including #s9 miners. Shit cn go south in a hurry.

#safestr

Reply to this note

Please Login to reply.

Discussion

Maybe use a gfci outlet or breaker

A GFI protects people from shocks by sensing low current (5mA) ground faults. This cord got real hot from an overload or loose connection. A GFI probably wouldn't have helped.

Any way to prevent it? It was plugged into the wall directly.

I'd start by replacing the cord and receptacle. It was probably a loose connection, creating heat, makibg the connection looser. Make sure everything is rated for the current you expect your device to draw. Then measure how much current it is actually drawing to make sure it is working right.

Thank you sir

Ooof, any idea where it went wrong?

Mining too hard!

I had same thing happen on an outdoor outlet. Outlet wire corroded and caused it to overheat on large draw. I would recommend removing outlet And inspecting or maybe replacing. Or plug it in again if you want to try for the insurance money;)

Thanks for the advice.