Voltage measured by a voltmeter is not the same as voltage across the resistive load of the miner.

Wall warts frequently fail in a way where they have correct voltage across no load like a multimeter but are unable to supply enough current at that voltage causing the voltage to drop under load.

You can measure on the pads of the barrel connection on the board while it is running to see if the voltage is lower than you measured on the power supply with no load.

Too complicated? You can just try another known good power supply with the same specs.

TLDR, or didn't understand, it might still be the power supply even if voltage looks good on a multimeter.

Reply to this note

Please Login to reply.

Discussion

Took another look at your image. That would definitely show up by measuring the female barrel connector on the board while it is running if it is the power supply.

Yeah I def don’t understand. 😄

But I have thought about trying to power cable from my other Bitaxe since it’s still working correctly. Thanks.

How did you double check the existing power cable?

Unplugged it and plugged it back in. 😂